‧AC‧
MEA180G
Sinwan AC Motor Dia.92 x L.80
Max. Loading 80W, UL/CUL, IP56
  Rated
Voltage
Freq Rated
Loading
Input
Ref.
Loading
Speed
No Loading Free Running Locked Rotor
Seized Motor
No Loading
Staring
UL
Input Current Speed Input Current Voltage  
Model No VAC Hz Watt RPM

Watt

Amp RPM Watt Amp VAC  
MEA180GAN11-1B** 115 50/60 60/80 2750/3250 32/24 0.37/0.21 2950/3600 102/107 0.86/0.87 26/27 £
MEA180GAN11-2B** 115 50/60 55/65 2300/2200 28/22 0.25/0.20 2950/3600 81/82 0.70/0.69 26/27 £
MEA180GAN11-3B** 115 50/60 20/30 1500/1600 20/16 0.18/0.14 1500/1800 44/42 0.34/0.33 26/27 £
MEA180GAN11-4B** 115 50/60 18/25 1100/1000 16/12 0.14/0.11 1500/1800 23/34 0.17/0.26 26/27 £
MEA180GAN11-1/2B**
dual rating
115 50/60 60/80
55/65
2750/3250
2300/2200
32/24
28/22
0.37/0.21
0.25/0.20
2950/3600
2950/3600
102/107
81/82
0.86/0.87
0.70/0.69
26/27
26/27
£
MEA180GAN11-3/4B**
dual rating
115 50/60 20/30
18/25
1500/1600
1100/1000
20/16
16/12
0.18/0.14
0.14/0.11
1500/1800
1500/1800
44/42
23/34
0.34/0.33
0.17/0.26
26/27
26/27
£
MEA180GAN22-1B** 230 50/60 60/80 2750/3250 32/24 0.19/0.10 2950/3600 102/107 0.43/0.44 38/40 £
MEA180GAN22-2B** 230 50/60 55/65 2300/2200 28/22 0.13/0.10 2950/3600 81/82 0.35/0.34 38/40 £
MEA180GAN22-3B** 230 50/60 20/30 1500/1600 20/16 0.09/0.07 1500/1800 44/42 0.17/0.16 38/40 £
MEA180GAN22-4B** 230 50/60 18/25 1100/1000 16/12 0.07/0.06 1500/1800 23/34 0.09/0.06 38/40 £
MEA180GAN22-1/2B**
dual rating
230 50/60 60/80
55/65
2750/3250
2300/2200
32/24
28/22
0.19/0.10
0.13/0.10
2950/3600
2950/3600
102/107
81/82
0.43/0.44
0.35/0.34
38/40
38/40
£
MEA180GAN22-3/4B**
dual rating
230 50/60 20/30
18/25
1500/1600
1100/1000
20/16
16/12
0.09/0.07
0.07/0.06
1500/1800
1500/1800
44/42
23/34
0.17/0.16
0.09/0.06
38/40
38/40
£
MEA180GAN11/22-1B**
dual voltage
115
230
50/60
50/60
60/80
60/80
2750/3250
2750/3250
32/24
32/24
0.37/0.21
0.19/0.10
2950/3600
2950/3600
102/107
102/107
0.86/0.87
0.43/0.44
26/27
38/40
£
MEA180GAN11/22-2B**
dual voltage
115
230
50/60
50/60
55/65
55/65
2300/2200
2300/2200
28/22
28/22
0.25/0.20
0.13/0.10
2950/3600
2950/3600
81/82
81/82
0.70/0.69
0.35/0.34
26/27
38/40
£
MEA180GAN11/22-3B**
dual voltage
115
230
50/60
50/60
20/30
20/30
1500/1600
1500/1600
20/16
20/16
0.18/0.14
0.09/0.07
1500/1800
1500/1800
44/42
44/42
0.34/0.33
0.17/0.16
26/27
38/40
£
MEA180GAN11/22-4B**
dual voltage
115
230
50/60
50/60
18/25
18/25
1100/1000
1100/1000
16/12
16/12
0.14/0.11
0.07/0.06
1500/1800
1500/1800
23/34
23/34
0.17/0.26
0.09/0.06
26/27
38/40
£
MEA180GAN8-1B** 48 50/60 60/80 2750/3250 32/24 0.67/0.51 2950/3600 102/107 2.13/2.23 16/17 £
MEA180GAN38-1B** 380 50/60 60/80 2750/3250 32/24 0.09/0.07 2950/3600 102/107 0.27/0.29 56/67 £
MEA180GAN48-1B** 440 50/60 60/80 2750/3250 32/24 0.07/0.06 2950/3600 102/107 0.22/0.23 76/87 £
  • **= DC / DR / UC / UR / DUC / DUR / NC / NR, for full model No. click “Nomenclature”.
    First *=D, U, DU, N description of shaft outlet position, second *=C, R description of motor rotating direction C-CW , R-CCW.
    Example: MEA180GAN11-1BDR, **/DR= Shaft outlet- D type, motor rotating direction viewed from rotor CCW-R type
  • 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380, 440, 480V... 50/60Hz, & any voltages available.
  • Dual speed High/Medium 1/2, Medium/Low 2/3 available on request.
  • Sinwan reserves the right to change data and improve electrical & mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: Capacitor induction, outer rotor, single phase, thermally protected
      IP Protection: IP56, UL, CUL approved E329400
      Frame: Aluminum diecasting motor frame, mounting holes dia.3.2mm self tapping or tapped M4
      Bearing: Two ball bearings
      Shaft: Stainless steel SUS420J2,dia.8mm, Customer's design available
      Weight: 1,300g (2.87Lbs)
      Dielectric Strength: Over 1 min. at 1,500 VAC, 50/60Hz
      Insulation Resistance: Over 100 MΩ at DC 500V
      Signal Output: Motor slow down alarm R/D, tacho speed sensor F/G
      Operating Temp: Acceptable -25°C~75°C, storage -30°C~+105°C
      Life Expectancy: No loading 80K hours at 45°C, 50K at 60°C, operation life decided in loading